Process Transmitters
The QDP-PROCESS 5600 Series is a smart differential-pressure transmitter for demanding process duty across oil, gas and chemical plant. It measures differential pressure for flow, level and filter monitoring, and offers 4–20 mA with HART and Modbus RTU so one model serves analogue loops and digital networks. High ±0.05 % FS accuracy, a fast response and a 1/4-18 NPT process connection make it a dependable choice for closed-loop process control. Choose the 5600 for direct-mounted DP where accuracy matters most; the QDP-PROCESS 5400 adds remote seals and hazardous-area approvals for harder installations.
Measurement range
0–100 bar configurable
Accuracy
±0.05 % FS
Output / communications
4–20 mA, HART and Modbus RTU / RS485
Process connection
NPT threaded options
Process temperature
−50 to 85 °C
Approvals / Protection
ATEX / IECEx, up to IP67
| Pressure type | Differential Pressure |
|---|---|
| Response time | ≤100 ms |
| Max. working pressure | Line pressure 420 bar; one‑sided overload 250 bar (200 bar for 100 bar range) |
| Process / ambient temperature | −50…85 °C (without LCD); −40…70 °C (with LCD) |
| Power supply | 18.3–44 V DC; 18.3–30 V DC (IS) |
| Outputs | 4–20 mA (2‑wire) |
| Environmental rating | IP66; IP67 |
| Electrical connection | M20×1.5; 1/2 NPT; Waterproof cable gland (IP67) |
| Housing material | Aluminium alloy (coated) or 316L stainless steel |
| Weight | ≈ 4 kg |
| Other ratings / standards | Vibration effect < 0.1 %; long-term stability ±0.1 %SPAN / 10 years |